  • 2. Conventional Bracing. Shasta County. Department of Resource Management. Building Division. 1855 Placer Street, Suite 102 Redding, CA 96001-1759. (530) 225-5761 * Fax (530) 245-6468. Handout. 118. 08/08. Page 2 of 4. braced wall panels shall be attached to joists, rafters or full depth blocking and extend to the roof framing at the exterior walls and at not more than 50-foot intervals. When trusses are used the solid blocking or other approved means may be used to transfer& ...


  • wall bracing provisions should meet the requirements of the california Residential Code (CRC), primarily. Section R602.10. If the wall bracing provisions cannot be satisfied, then an engineered design shall be provided. Portions of the building that do not meet the items below must be designed by a california licensed architect or civil or structural engineer using accepted ... braced wall panel (BWP) Material (Table R602.10.4) i. Wood Structural panels (WSP) 3/8”& ...


  • (d) Irregular Buildings. Amend Section R.5 to the california Residential Code to read as follows: R.5. 1. When exterior shear wall lines or braced wall panels are not in one plane vertically from the foundation to the uppermost story in which they are required. 2. When a section of floor or roof is not laterally supported by shear walls or braced wall lines on all edges. 3. When the end of a braced wall panel occurs over an opening in the wall below. 4. When an opening& ...


  • Portions of the building that exceed the limits of the items below must be designs by a california licensed civil or structural engineer using accepted engineering practice: 1. The provision of the conventional light frame construction shall comply with the following limitations a. The number of stories shall not exceed two for single family residences and duplexes and one story for all other occupancies. b. Floor to floor and floor to roof heights of bearing walls and braced panels shall not& ...


  • wall bracing lengths are based on a soil site class “D.” Interpolation of bracing length between the Sds values associated with the seismic design categories shall be permitted when a site-specific Sds value is determined in accordance with Section 1613.3 of the california Building Code. Where the braced wall line length is greater than 50 feet, braced wall lines shall be permitted to be divided into shorter segments having lengths of 50 feet or less, and the amount of bracing within& ...


  • requirements for lateral bracing of small wood- frame structures in the high seismic regions of. British Columbia. Designers will need to consider these requirements when creating the form of the exterior walls, as well as the dimensions and locations of interior walls. Builders will need to understand the material requirements, as well as the construction methods necessary to fabricate braced wall panels at required locations throughout the structure. The simple basis of improving the.


  • methods, location and length of braced wall panels, foundation requirements of braced wall panels at top and bottom shall be provided. Parts of the following may reference the International Residential Code for examples and additional explanations. The current edition of the california Residential Code is what is required for design and is used in plan review. wall bracing provisions should meet the requirements of the california Residential Code (CRC), primarily. Section R602.10.


  • wall bracing methods of the CRC. All other projects must use the california Building Code (CBC). ... Roofs or floors that are not supported on all four sides by braced wall lines, except that roof overhangs and/or balconies may extend up to 6' beyond a braced wall line. 3. When the end of a braced wall panel extends more than one foot over an opening below unless& ...


  • Construction of braced wall panels shall be by one of the methods found under “Permitted Types of braced wall panels”. braced wall panel sole plates shall be nailed to the floor framing with 3-16d nails per 16” on center. Blocking between joists& ...


  • frame, light frame with veneer, and concrete or masonry. The values are also based on the type of foundations: slab on grade, crawl space, or basement. (portion of table shown see CRC for complete tables). R403.1.2 &. R.1. Continuous footing in Seismic Design Categories D₀,. D₁, and D₂. Clarifies the continuous footing requirements and moves the requirement for braced wall panel support for seismic categories Seismic Design Categories (SDC). D₀, D₁, and D2& ...


  • Section R602.10 of the International Residential Code calls for "braced wall lines" composed of "braced wall panels." The location, width, and construction details of these braced wall panels, as well as the materials that can be used to build them, are spelled out in the code's text, tables, and illustrations, but it's not a simple prescription. Here's a clear path through the maze of options.


  • line. braced wall panels shall be a minimum of 4 feet in length or one half of the floor to ceiling height whichever is greater. The sum of lengths of braced wall panels at each braced wall line shall conform to the wall bracing table below, or see california Building Code (CBC) table 2308.12.4. For wall lengths greater or lesser than 25 feet the total length of required bracing shall be at the same ratio as the table below, except that the requirements earlier this paragraph shall still apply.


  • a. wall bracing percentages are based on a soil site class “D.” Interpol ation of bracing percentage between the Sds values associated with the Seismic Design Categories shall be permitted when a site-specific Sds value is determined in accordance with Section 1613.5 of the International Building Code. b. Foundation cripple wall panels shall be braced in accordance with Section R602.10.8. c. Methods of bracing shall be as described in Sections R602.10.2 and R.


  • Sec. 2326.11.3. Bracing. braced wall lines shall consist of braced wall panels which meet the requirements for location, type and amount of bracing specified in Table 23-I-W and are in line or offset from each other by not more than 4 feet (1219 mm). braced wall panels shall start at not more than 8 feet (2438 mm) from each end of a braced wall line. All braced wall panels shall be clearly indicated on the plans. Construction of braced wall panels shall be by& ...


  • 9, Stud to stud and abutting studs at intersecting wall corners (at braced wall panels), 16d box (3<sup>1</sup>/2″ × 0.135″); or3″ × 0.131″ nails, 12″ o.c. face nail. 16d common (3<sup>1</sup>/2″ × 0.162″), 16″ o.c. face nail. 10, Built-up header (2″ to 2″ header with <sup>1</sup>/2″ spacer), 16d common (3<sup>1</sup>/2″ × 0.162″), 16″ o.c. each edge face nail. 16d box (3<sup>1</sup>/2″ × 0.135″), 12″ o.c. each edge face nail. 11, Continuous header to stud, 5-8d box (2<sup>1</sup>/2″ × 0.113″); or4-8d common (2<sup>1</sup>/2″ × 0.131″);& ...


  • You must be signed in to access the calculator. Welcome to the APA wall Bracing Calculator. This tool is intended to simplify the design of residential structures that comply with 2009, 2012, and/or 2015 International Residential Code (IRC) wall bracing requirements. This calculator is intended for use by experienced designers that are familiar with wall bracing. With the APA wall Bracing Calculator: Create a project and identify its pertinent details. Pictorially identify and calculate the& ...


  • Sole plate to joist or blocking at braced wall panels. 3-16d (31/2² ´ 0.135²). 16² o.c.. Double top plates, minimum 24-inch offset of end joints, face nail in lapped area. 8-16d (31/2² ´ 0.135²). —. Blocking between joists or rafters to top plate, toe nail. 3-8d (21/2² ´ 0.113²). —. Rim joist to top plate, toe nail. 8d (21/2² ´ 0.113²). 6² o.c.. Top plates, laps at corners and intersections, face nail. 2-10d (3² ´ 0.128²). —. Built-up header, two pieces with 1/2² spacer. 16d (31/2² ´ 0.135²). 16² o.c. along& ...


  • PRESCRIPTIVE wall BRACING. (R/CBC ). braced wall Lines. □ Provided on the exterior, and on interior at 25' max spacing. (Table R). □ In one and two story buildings, one room or equal not exceed- ing 900 sq. ft. may have walls not more than 35' apart (Table. R). □ walls within a braced wall line must not be offset by more than 4' (R). □ wall panels must start within 10' of the end of a braced wall line. Distance between& ...


  • site at: www.co.calaveras.ca.us/cc/Departments/BuiIdianepartment.aspx. Wind Design: 0 Wind Speed ... are required to be approved and stamped by a california licensed architect or engineer. All residences and ... _l___________al Pansel. 1. The total length of braced wall panels required along each braced wall line is dependent on the type of bracing method used and the spacing between the braced wall lines. The most common types of bracing methods used in Calaveras.